Product highlights
- robust Glass Reinforced Polyester (GRP) enclosures
- mounting options
- wide range of enclosure sizes
GRP Industrial and EX Enclosure
Please see our extensive range of standard boxes below.
Product description:
Glass Reinforced Polyester (GRP)
Our enclosures, made of glass fibre reinforced polyester (GRP), are just as robust as the standard aluminium enclosures despite their lower weight. In addition, the enclosures offer good electrical properties and behave dielectrically.
There is a wide range of industrial applications, such as mechanical engineering, as a classic terminal or distributor enclosure.
As standard, we supply the enclosures in the colour RAL 7001, with IP 66 protection class and a surrounding neoprene seal. For more demanding applications we also offer the enclosures in an explosion-proof ATEX and an Fire-Rated version.
We offer the following services for this product:
- Mechanical processing
- Powder coating / preferred colour
- Engraving
- Equipped with e.g. terminal strips, mounting plates
- Sample service
- Packaging according to customer specifications possible
Scope of delivery:
GRP Industrial Enclosures
- Lid
- Neoprene seal
- Stainless steel screws
GRP ATEX Enclosures
- Lid
- Silicone seal
- Stainless steel screws
- Erdungsanschluss
Technical data:
GRB Industrial
Material:
Glass Reinforced Polyester
IP:
IP 66 (IP67, IP68 on Request)
IK:
7 Joules
Service Temperature:
-40°C to +80°C (Neoprene)
-60° C to +110°C (Silicone)
Gasket:
Neoprene, Silicone
Color:
Black (RAL 9011), Grey (RAL 7000)
Surface Resistance:
1012Ω (Grey), 109Ω (Black)
Flammability:
V0 (UL 94)
Certifications:
CE, UL (only 13 sizes)
Part Code Prefix:
GRJ XX
GRP ATEX
Material:
Glass Reinforced Polyester-Graphite added
IP:
IP66
IK:
7 Joules
Service Temperature:
-60° C to +110°C (Silicone)
Gasket:
Silicone
Color:
Black (RAL 9011)
Surface Resistance:
109Ω (Black)
Flammability:
V0 (UL 94)
Certifications:
ATEX, IECEx, EAC
Part Code Prefix:
Component:
GRJ XXXXXX
Equipment:
SIRA-EXGRJ XXXXXX
PTB-EXEGRJ XXXXXX
GRP Fire Rated
Material:
Glass Reinforced Polyester
IP:
IP66
IK:
7 Joules
Service Temperature:
-40°C to +80°C (Neoprene)
-60° C to +110°C (Silicone)
Gasket:
Neoprene, Silicone
Color:
Black (RAL 9011), Grey (RAL 7000)
Surface Resistance:
1012Ω (Grey), 109Ω (Black)
Flammability:
V0 (UL 94)
Certifications:
BS 6387:2013
Part Code Prefix:
FRGJB XX
Downloads:
General Brochure
GRP Manual
GRP EX Manual
GRP Enclosure
Product Code | Dimensions (mm) | drawings | 3D Files | DIN Rail | Mounting plate | Allen lid screw | Sealable lid screw | External Mounting Bracket | External Hinge | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
L | W | H | BASE | LID | TS 15 | TS 35 | |||||||
GRJ-01 | 80 | 75 | 55 | 📝 | 📄 | 📄 | Y | Y | Y | Y | Y | Y | |
GRJ-02 | 110 | 75 | 55 | 📝 | 📄 | Y | Y | Y | Y | Y | Y | ||
GRJ-03 | 122 | 120 | 90 | 📝 | 📄 | 📄 | Y | Y | Y | Y | Y | Y | |
GRJ-04 | 80 | 75 | 75 | 📄 | 📄 | ||||||||
GRJ-05 | 160 | 75 | 55 | 📝 | 📄 | Y | Y | Y | Y | Y | Y | ||
GRJ-06 | 160 | 75 | 75 | 📝 | 📄 | Y | Y | Y | Y | Y | Y | ||
GRJ-07 | 160 | 160 | 90 | 📝 | Y | Y | Y | Y | Y | Y | |||
GRJ-08 | 110 | 75 | 75 | 📄 | |||||||||
GRJ-09 | 190 | 75 | 55 | 📝 | 📄 | Y | Y | Y | Y | Y | Y | ||
GRJ-10 | 190 | 75 | 75 | 📄 | |||||||||
GRJ-11 | 220 | 120 | 90 | 📝 | Y | Y | Y | Y | Y | Y | |||
GRJ-12 | 255 | 250 | 120 | 📝 | Y | Y | Y | Y | Y | Y | |||
GRJ-13 | 260 | 160 | 90 | 📝 | Y | Y | Y | Y | Y | Y | |||
GRJ-14 | 360 | 160 | 90 | 📝 | Y | Y | Y | Y | Y | Y | |||
GRJ-15 | 400 | 250 | 120 | 📝 | Y | Y | Y | Y | Y | Y | |||
GRJ-16 | 400 | 405 | 120 | 📝 | Y | Y | Y | Y | Y | Y | |||
GRJ-17 | 255 | 250 | 160 | 📄 | |||||||||
GRJ-18 | 400 | 250 | 160 | 📄 | |||||||||
GRJ-19 | 400 | 405 | 201 | 📄 | |||||||||
GRJ-20 | 600 | 250 | 121 | 📄 | 📄 | ||||||||
GRJ-21 | 600 | 250 | 161 | 📄 | 📄 |
GRP EX Enclosure
Product Code | Dimensions (mm) | drawings | DIN Rail | Mounting plate | Allen lid screw | External Mounting Bracket | External Hinge | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Component | Equipment | L | W | H | TS 15 | TS 35 | |||||
EX- GJB-807555-U | EX- E-GRJ-807555 | 80 | 75 | 55 | 📝 | Y | Y | Y | Y | ||
EX- GJB-1107555-U | EX- E-GRJ-1107555 | 110 | 75 | 55 | 📝 | Y | Y | Y | Y | ||
EX- GJB-12212090-U | EX- E-GRJ-12212090 | 122 | 120 | 90 | 📝 | Y | Y | Y | Y | Y | |
EX- GJB-1607555-U | EX- E-GRJ-1607555 | 160 | 75 | 55 | 📝 | Y | Y | Y | Y | ||
EX- GJB-1607575-U | EX- E-GRJ-1607575 | 160 | 75 | 75 | 📝 | Y | Y | Y | Y | ||
EX- GJB-16016090-U | EX- E-GRJ-16016090 | 160 | 160 | 90 | 📝 | Y | Y | Y | Y | Y | |
EX- GJB-1907555-U | EX- E-GRJ-1907555 | 190 | 75 | 55 | 📝 | Y | Y | Y | Y | ||
EX- GJB-22012090-U | EX- E-GRJ-22012090 | 220 | 120 | 90 | 📝 | Y | Y | Y | Y | Y | |
EX- GJB-255250120-U | EX- E-GRJ-255250120 | 255 | 250 | 120 | 📝 | Y | Y | Y | Y | Y | |
EX- GJB-26016090-U | EX- E-GRJ-26016090 | 260 | 160 | 90 | 📝 | Y | Y | Y | Y | Y | |
EX- GJB-36016090-U | EX- E-GRJ-36016090 | 360 | 160 | 90 | 📝 | Y | Y | Y | Y | Y | |
EX- GJB-400250120-U | EX- E-GRJ-400250120 | 400 | 250 | 120 | 📝 | Y | Y | Y | Y | Y | |
EX- GJB-400405120-U | EX- E-GRJ-400405120 | 400 | 405 | 120 | 📝 | Y | Y | Y | Y | Y |